01 / Construction & ratings
Construction & ratings
- ASTM B8-99 Concentric-Lay-Stranded Copper Conductors
- BS 7884 Copper stranded conductor for overhead electric traction and power transmission systems
- AS/NZS Standard Concentric-Lay-Stranded Copper Conductors
02 / Technical data
Technical data
Product identifiers, units and manufacturer specification data are kept in their original form.
| Table 1 BS 7884 | ||||||
|---|---|---|---|---|---|---|
| Nominal cross-section area of stranded conductor mm2 | Construction (stranding and wire diameter) number/mm | Overall diameter of conductor (approx.) mm | Nominal mass per unit length kg/km | Resistance at 20℃ | Minimum breaking load N | |
| Nominal /km | Max. /km | |||||
| 10 | 7/1.35 | 4.05 | 89.82 | 1.788 | 1.829 | 3752 |
| 14 | 7/1.60 | 4.8 | 126.2 | 1.273 | 1.303 | 5267 |
| 16 | 3/2.65 | 5.7 | 148.3 | 1.082 | 1.106 | 6194 |
| 16 | 7/1.70 | 5.1 | 142.4 | 1.128 | 1.154 | 5946 |
| 25 | 7/2.10 | 6.3 | 217.3 | 0.7391 | 0.7563 | 9073 |
| 32 | 3/3.75 | 8.06 | 296.9 | 0.5405 | 0.552 | 12400 |
| 32 | 7/2.46 | 7.38 | 298.2 | 0.5386 | 0.5497 | 12442 |
| 35 | 7/2.50 | 7.5 | 308 | 0.5215 | 0.5337 | 12860 |
| 50 | 7/3.00 | 9 | 443.5 | 0.3622 | 0.3706 | 18520 |
| 50 | 19/1.80 | 9 | 435.8 | 0.3727 | 0.3819 | 17700 |
| 70 | 7/3.55 | 10.65 | 621.1 | 0.2586 | 0.2646 | 25930 |
| 70 | 19/2.10 | 10.5 | 593.2 | 0.2738 | 0.2806 | 24090 |
| 95 | 19/2.50 | 12.5 | 840.7 | 0.1932 | 0.198 | 34140 |
| 100 | 7/4.30 | 12.9 | 911.2 | 0.1763 | 0.181 | 36540 |
| 120 | 19/2.80 | 14 | 1055 | 0.154 | 0.1578 | 42830 |
| 125 | 19/2.90 | 14.5 | 1131 | 0.1436 | 0.1471 | 45940 |
| 150 | 19/3.20 | 16 | 1377 | 0.118 | 0.1208 | 55940 |
| 150 | 37/2.25 | 15.75 | 1334 | 0.1233 | 0.1264 | 53880 |
| 185 | 19/3.55 | 17.75 | 1695 | 0.09582 | 0.09815 | 68860 |
| 185 | 37/2.50 | 17.5 | 1647 | 0.09981 | 0.1024 | 66490 |
| Table 2 AS/NZS Standard | |||||||
|---|---|---|---|---|---|---|---|
| Number of stranding | Wire diameter mm | Approx. overall diameter mm | Cross-sectional area mm2 | Mass per km kg | Calculated breaking load kN | Equivalent aluminium area mm2 | DC resistance km at 20℃ |
| 7 | 1 | 3 | 5.498 | 49.3 | 2.32 | 8.68 | 3.25 |
| 7 | 1.25 | 3.75 | 8.589 | 76.9 | 3.59 | 13.6 | 2.09 |
| 7 | 1.75 | 5.25 | 16.84 | 151 | 6.89 | 26.6 | 1.06 |
| 7 | 2 | 6 | 21.99 | 197 | 8.89 | 34.7 | 0.815 |
| 7 | 2.75 | 8.25 | 41.58 | 375 | 16.2 | 65.3 | 0.433 |
| 19 | 1.75 | 8.75 | 45.7 | 413 | 18.3 | 71.7 | 0.395 |
| 19 | 2 | 10 | 59.7 | 538 | 23.6 | 93.6 | 0.303 |
| 7 | 3.5 | 10.5 | 67.35 | 607 | 25.4 | 106 | 0.268 |
| 7 | 3.75 | 11.3 | 77.28 | 696 | 28.8 | 121 | 0.233 |
| 37 | 1.75 | 12.3 | 88.99 | 806 | 35.6 | 139 | 0.203 |
| 19 | 2.75 | 13.8 | 112.9 | 1020 | 43.1 | 177 | 0.16 |
| 19 | 3 | 15 | 134.3 | 1210 | 50.8 | 211 | 0.134 |
| 37 | 2.5 | 17.5 | 181.6 | 1640 | 70.3 | 284 | 0.0996 |
| 37 | 2.75 | 19.3 | 219.8 | 1990 | 83.9 | 344 | 0.0826 |
| 37 | 3 | 21 | 261.6 | 2370 | 98.9 | 409 | 0.0691 |
| 61 | 2.75 | 24.8 | 362.3 | 3290 | 138 | 566 | 0.5 |
Before you specify
What information should I include in an inquiry?
Include the product designation, operating voltage, conductor size, number of cores, required length and delivery destination. Add installation conditions and any required standard.
Can I use these tables to make the final cable selection?
Use the published values to compare products. Confirm the final construction, current rating and installation requirements with your project engineer and the supplier.
How can I keep a copy of this specification?
Use Print / Save PDF on this page. The print layout includes the product name, construction details and specification tables.
Can the team review a project specification?
Send your requirements through the inquiry form. Include the relevant drawings or document references in your message so the team can follow up.