Products

1.9/3.3(3.6)kV XLPE Insulated Single Core and 3Cores Power Cable (AS/NZS 1429.1)

Review the construction and specification data below to compare this cable with your project requirements.

01 / Construction & ratings

Construction & ratings

  • Conductor – Plain annealed class 2 compacted copper
  • Conductor screen – Semi-conductive compound
  • Insulation – Cross linked polyethylene (XLPE)
  • Insulation screen – Semi-conductive compound
  • Metallic screen – Plain annealed copper wire
  • PP rope filler
  • Binder tape – Non-hygroscopic material tape
  • Separation layer – Polyvinyl chloride compound (PVC 5V-90)
  • Armor – Hard drawn aluminum wires for single core or Galvanized steel wire for multi core
  • Outer sheath – Polyvinyl chloride compound (PVC 5V-90)
1.9/3.3(3.6)kV XLPE Insulated Single Core and 3Cores Power Cable (AS/NZS 1429.1)

02 / Technical data

Technical data

Product identifiers, units and manufacturer specification data are kept in their original form.

1.9/3.3(3.6)kV XLPE Insulated Single Core and 3Cores Power Cable (AS/NZS 1429.1) · 01
Nominal conductor areamm²2535507095120150185240300400500630
Conductor diametermm6.17.08.210.011.613.014.616.218.420.623.426.630.0
Nominal insulation thicknessmm2.02.02.02.02.02.02.02.02.02.02.02.22.4
Nominal insulation diametermm11.512.513.715.517.118.520.121.723.926.128.932.536.3
Nominal screen area on each coremm²24.434.448.768.168.168.768.768.768.768.768.768.768.7
Approx.cable diametermm26.728.729.932.434.234.937.539.341.743.946.952.156.3
Approx.weightkg/km1101134416292086239426513065347040904710561569778470
Min. bending radius of duringinstallationmm52056058063067068073077082086092010201100
Min. bending radius of after installationmm350370390420450460490510550570610680730
Max. pulling tension of conductorkN1.72.43.44.86.58.210.212.616.420.427.234.042.9
Max. DC. Resistance of conductor at 20 ℃ohm/km0.7270.5240.3870.2680.1930.1530.1240.09910.07540.06010.04700.03660.0283
Max. AC. Resistance of conductor at 90 ℃ohm/km0.9270.6680.4940.3420.2470.1960.1600.1290.09920.08060.06500.05300.0439
Inductance,trefoil,touchingmH/km0.4840.4710.4470.4240.4050.3860.3770.3660.3520.3400.3280.3230.315
Conductor to screen capacitanceμF/km0.3250.3490.3910.4520.5070.5540.6090.6630.7380.8130.9080.9320.958
Min Insulation resistance @20℃Mohm. km6803632656604890436339883631333329952720243523722308
Fault current capacity of phase conductorKA/1s3.65.07.210.013.617.221.526.534.342.957.271.590.1
Fault current capacity of metallic screenKA/1s3.65.17.210.110.110.210.210.210.210.210.210.210.2
current rating – Ground,direct buriedA145174205250296335370415475530595660735
current rating – In free air unclose spaceA145175210265320365415470555630725830945
current rating – In ground single way ductA140170195230270300325360405440490540595
1.9/3.3(3.6)kV XLPE Insulated Single Core and 3Cores Power Cable (AS/NZS 1429.1) · 02
Nominal conductor areamm²2535507095120150185240300400
Conductor diametermm6.07.08.210.011.613.014.616.218.420.623.4
Nominal insulation thicknessmm2.02.02.02.02.02.02.02.02.02.02.0
Nominal insulation diametermm11.512.513.715.517.118.520.121.723.926.128.9
Nominal screen area on each coremm²25.534.049.468.168.168.168.168.168.168.168.1
Approx.cable diametermm46.548.953.158.061.665.069.172.777.984.591.4
Approx.weightkg/km357741385320655176128639982811166132891648719696
Min. bending radius of duringinstallationmm910960104011301200127013501420152016501780
Min. bending radius of after installationmm610640690760800850900950101011001190
Max. pulling tension of conductorkN5.17.110.214.319.424.530.637.749.061.281.6
Max. DC. Resistance of conductor at 20 ℃ohm/km0.7270.5240.3870.2680.1930.1530.1240.09910.07540.06010.0470
Max. AC. Resistance of conductor at 90 ℃ohm/km0.670.4940.3420.2460.1960.1590.1270.0970.07800.06160.0488
Inductance,trefoil,touchingmH/km0.3810.3630.3450.3240.3100.3000.2910.2820.2730.2660.258
Conductor to screen capacitanceμF/km0.3150.3490.3910.4520.5070.5540.6090.6630.7380.8130.908
Min Insulation resistance @20℃Mohm. km70176326566048904363398836313333299527202435
Fault current capacity of phase conductorKA/1s3.65.07.210.013.617.221.526.534.342.957.2
Fault current capacity of metallic screenKA/1s3.85.07.310.110.110.110.110.110.110.110.1
current rating – Ground,direct buriedA140165195240290335365410475520558
current rating – In free air unclose spaceA135160190240290340380435510590678
current rating – In ground single way ductA120140165205240275310350405450514
1.9/3.3(3.6)kV XLPE Insulated Single Core and 3Cores Power Cable (AS/NZS 1429.1) · 03
Temp.(℃)20253540455055
Rating factor1.181.141.0510.950.890.84
1.9/3.3(3.6)kV XLPE Insulated Single Core and 3Cores Power Cable (AS/NZS 1429.1) · 04
Temp.(℃)10152025303540
Rating factor1.111.071.0410.960.920.88
1.9/3.3(3.6)kV XLPE Insulated Single Core and 3Cores Power Cable (AS/NZS 1429.1) · 05
Depth of burial (m)Rating factor up to 300mm²Rating factor above 300mm²Rating factor above 300 mm² single coreRating factor above 300 mm² three core
0.801.001.001.001.00
1.000.980.970.980.99
1.250.960.950.950.97
1.500.950.930.940.96
1.750.940.910.920.96
2.000.920.890.910.95
2.500.910.880.890.94
3.000.900.860.880.93
1.9/3.3(3.6)kV XLPE Insulated Single Core and 3Cores Power Cable (AS/NZS 1429.1) · 06
Nominal area of conductor (mm²)Thermal resistivity (℃.m/W)0.80.91.01.21.52.02.53.0
Single coreRating factors
up to 1501.161.111.071.000.910.810.730.67
180 to 4001.171.121.081.000.900.800.720.66
above 4001.181.131.081.000.900.790.710.65
Three-coreRating factors
up to 161.091.061.041.000.950.870.790.74
25 to 1501.141.101.071.000.930.840.760.70
185 to 4001.161.111.071.000.920.820.740.68

Before you specify

What information should I include in an inquiry?

Include the product designation, operating voltage, conductor size, number of cores, required length and delivery destination. Add installation conditions and any required standard.

Can I use these tables to make the final cable selection?

Use the published values to compare products. Confirm the final construction, current rating and installation requirements with your project engineer and the supplier.

How can I keep a copy of this specification?

Use Print / Save PDF on this page. The print layout includes the product name, construction details and specification tables.

Can the team review a project specification?

Send your requirements through the inquiry form. Include the relevant drawings or document references in your message so the team can follow up.

Related cables

Contact us

Bring your next connection into focus.

Share your application, working voltage, cable size and destination. Our team can help you identify the next step.